Building type:
|
Family
Residence
|
|
Location:
|
Mountbellew,
Co. Galway
|
|
Year of construction:
|
2004-2005
|
|
Type of construction
|
Block
& Internal dry lining insulation
|
|
Total Floor area (m2)
|
190
m²
|
|
Number of storeys:
|
2
|
|
Type of heat distribution system:
|
Forced
air ventilation
|
|
% of total floor area heated:
|
100%
|
|
Design outdoor temperature (ºC)
|
Heating:
|
-3
|
Cooling:
|
-
N/A
|
|
Design indoor temperature (ºC)
|
Heating:
|
21
|
Cooling:
|
-
N/A
|
|
|
|
|
Heating
and cooling Loads
|
|
Application:
|
Space
heating only
|
|
Heat pump type(s):
|
Water-to-air
|
|
Manufacturer
|
Waterfurnace
|
|
Cooling:
|
-
|
|
Model
|
EKW08
|
|
Heat pump installed capacity (KW)
|
Heating:
8Kw
|
|
Refrigerant:
|
R-410A
|
|
Heat source
|
Ground
|
|
Details (circulating pumps):
|
245
W (ground-source) + 200W (Fan or air only)
|
|
a) Type of ground heat exchanger:
|
Horizontal
collector
|
|
b) Trench depth (m):
|
1
m
|
|
c) Pipe length (m):
|
600m
|
|
d) Heat transfer fluid:
|
Water/glycol
20%
|
|
|
|
|
Distribution system(s):
|
|
|
Cooling:
|
-
Available
|
|
Supply and return temperature (ºC)
|
|
18/30
air
|
|
24/15 air
|
|
|
|
|
|
|
|
Hot water capacity
|
300
L
|
|
Auxiliary system:
|
None
|
|
Heat pump design:
|
100%
of heat loss – but probably higher as the insulation is extremely
well done
|
|
Supplementary system:
|
Open
fireplaces
|
|
Ventilation
|
Integrated
heat recovery ventilation
|
|
Heat pump system completion date:
|
Early
/ mid 2005
|
|
|
|
|
|